0
TECHNICAL PAPERS

Wear Measurements of Diamond-Like Carbon Coated Proximity Recording Sliders Using Raman Spectroscopy

[+] Author and Article Information
Hidekazu Kohira

Data Storage & Retrieval Systems Division, Hitachi, Ltd., 2880 Kozu, Odawara-shi, Kanagawa, 256-8510, Japan

F. E. Talke

Center for Magnetic Recording Research, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92093-0401

J. Tribol 122(1), 288-292 (Jun 30, 1999) (5 pages) doi:10.1115/1.555355 History: Received March 04, 1999; Revised June 30, 1999
Copyright © 2000 by ASME
Your Session has timed out. Please sign back in to continue.

References

Machcha,  A., McMillan,  T., and Talke,  F. E., 1996, “The Tribology of Tri-pad Sliders with Hydrogenated and Nitrogenated Disks,” IEEE Trans. Magn., 32, No. 5, pp. 3654–3655.
Hsia,  Y. T., Rottmayer,  B., and Donovan,  M. J., 1996, “A New Wear Measurement Technique for Pseudo-Contact Magnetic Recording Heads,” IEEE Trans. Magn., 32, No. 5, pp. 3750–3752.
Varansasi,  S. S., Lauer,  J. L., Talke,  F. E., Wang,  Geng, and Judy,  J. H., 1997, “Friction and Wear Studies of Carbon Overcoated Thin Films Magnetic Sliders: Application of Raman Microspectroscopy,” ASME J. Tribol., 119, pp. 471–475.

Figures

Grahic Jump Location
Schematic of subambient pressure slider
Grahic Jump Location
Flying height versus velocity and skew angle for a number of sliders
Grahic Jump Location
Pitch angle versus velocity and skew angle for a number of sliders
Grahic Jump Location
Slider coordinate system and Raman measurement points
Grahic Jump Location
AE output versus time for typical start/stop cycle
Grahic Jump Location
Typical raw Raman spectrum: intensity as a function of wave number and duration of seek test
Grahic Jump Location
Typical deconvoluted Raman spectrum (Gaussian fit): ID is peak intensity of D-band and IG is peak intensity of G-band
Grahic Jump Location
Raman intensity of G-band versus carbon thickness
Grahic Jump Location
Raman intensity of G-band for point A and point E versus seek time
Grahic Jump Location
Raman intensity of G-band near trailing edge after 500 second seek test
Grahic Jump Location
Raman intensity of G-band versus time during “track following”
Grahic Jump Location
Raman intensity of G-band versus seek time and spindle speed for point A near trailing edge
Grahic Jump Location
Raman intensity of G-band versus sliding distance for point A near trailing edge
Grahic Jump Location
Raman intensity of G-band versus seek time and interference height for point A near trailing edge
Grahic Jump Location
Raman intensity of G-band versus seek time and seek frequency

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org