Abstract
This paper proposes a novel wearable device to monitor and record the posture and alignment of spine. The proposed device adopts an underactuated mechanism design which allows it to adapt to the multiple-degrees-of-freedom spinal posture with minimum weight and complexity. To ensure the validity of measurement and comfort of wearing, the mechanism parameters are determined first by considering a special posture and then are fine-tuned using an optimization algorithm so that uniform contact forces for several selected spinal postures can be achieved. Experiments demonstrate that the device can automatically maintain contact with the wearer’s back and offer real-time spinal posture and alignment data for medical diagnosis and treatment.
Issue Section:
Special Issue: Selected Papers from IDETC-CIE 2023
Graphical Abstract Figure
Issue Section:
Special Issue: Selected Papers from IDETC-CIE 2023
References
1.
Masud
, T.
, and Morris
, R. O.
, 2001
, “Epidemiology of Falls
,” Age Ageing
, 30
(Suppl_4
), pp. 3
–7
. 2.
Kasukawa
, Y.
, Miyakoshi
, N.
, Hongo
, M.
, Ishikawa
, Y.
, Noguchi
, H.
, Kamo
, K.
, Sasaki
, H.
, Murata
, K.
, and Shimada
, Y.
, 2010
, “Relationships Between Falls, Spinal Curvature, Spinal Mobility and Back Extensor Strength in Elderly People
,” J. Bone Mineral Metab.
, 28
, pp. 82
–87
. 3.
Imagama
, S.
, Ito
, Z.
, Wakao
, N.
, Seki
, T.
, Hirano
, K.
, Muramoto
, A.
, Sakai
, Y.
, Matsuyama
, Y.
, Hamajima
, N.
, Ishiguro
, N.
, and Hasegawa
, Y.
, 2013
, “Influence of Spinal Sagittal Alignment, Body Balance, Muscle Strength, and Physical Ability on Falling of Middle-Aged and Elderly Males
,” Eur. Spine J.
, 22
, pp. 1346
–1353
. 4.
Le Huec
, J.
, Thompson
, W.
, Mohsinaly
, Y.
, Barrey
, C.
, and Faundez
, A.
, 2019
, “Sagittal Balance of the Spine
,” Eur. Spine J.
, 28
, pp. 1889
–1905
. 5.
Porto
, A. B.
, and Okazaki
, V. H.
, 2018
, “Thoracic Kyphosis and Lumbar Lordosis Assessment by Radiography and Photogrammetry: A Review of Normative Values and Reliability
,” J. Manipulative Physiol. Ther.
, 41
(8
), pp. 712
–723
. 6.
Schwab
, F.
, Patel
, A.
, Ungar
, B.
, Farcy
, J.-P.
, and Lafage
, V.
, 2010
, “Adult Spinal Deformity–Postoperative Standing Imbalance: How Much Can You Tolerate? An Overview of Key Parameters in Assessing Alignment and Planning Corrective Surgery
,” Spine
, 35
(25
), pp. 2224
–2231
. 7.
Roveda
, L.
, Savani
, L.
, Arlati
, S.
, Dinon
, T.
, Legnani
, G.
, and Tosatti
, L. M.
, 2020
, “Design Methodology of an Active Back-Support Exoskeleton With Adaptable Backbone-Based Kinematics
,” Int. J. Ind. Ergon.
, 79
, p. 102991
. 8.
Plamondon
, A.
, Delisle
, A.
, Larue
, C.
, Brouillette
, D.
, McFadden
, D.
, Desjardins
, P.
, and Larivière
, C.
, 2007
, “Evaluation of a Hybrid System for Three-Dimensional Measurement of Trunk Posture in Motion
,” Appl. Ergon.
, 38
(6
), pp. 697
–712
. 9.
Sardini
, E.
, Serpelloni
, M.
, and Pasqui
, V.
, 2015
, “Daylong Sitting Posture Measurement With a New Wearable System for at Home Body Movement Monitoring
,” 2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
, Pisa, Italy
, May 11–14
, IEEE, pp. 652
–657
.10.
Fodor
, C.
, Rotariu
, C.
, Andruseac
, G.
, and Costin
, H.
, 2019
, “Device for Telemonitoring of Spine Flexion During Cervical Kyphosis Treatment
,” 2019 11th International Symposium on Advanced Topics in Electrical Engineering (ATEE)
, Bucharest, Romania
, Mar. 28–30
, IEEE, pp. 1
–4
.11.
Voinea
, G.-D.
, Butnariu
, S.
, and Mogan
, G.
, 2016
, “Measurement and Geometric Modelling of Human Spine Posture for Medical Rehabilitation Purposes Using a Wearable Monitoring System Based on Inertial Sensors
,” Sensors
, 17
(1
), p. 3
. 12.
Wong
, W. Y.
, and Wong
, M. S.
, 2008
, “Trunk Posture Monitoring With Inertial Sensors
,” Eur. Spine J.
, 17
, pp. 743
–753
. 13.
Birglen
, L.
, Laliberté
, T.
, and Gosselin
, C. M.
, 2007
, Underactuated Robotic Hands
, Springer
, Berlin
.14.
Belzile
, B.
, and Birglen
, L.
, 2017
, “Optimal Design of Self-Adaptive Fingers for Proprioceptive Tactile Sensing
,” ASME J. Mech. Rob.
, 9
(5
), p. 051004
. 15.
Sivanandam
, S.
, Deepa
, S.
, Sivanandam
, S.
, and Deepa
, S.
, 2008
, Genetic Algorithms
, Springer
, Berlin
.Copyright © 2024 by ASME
You do not currently have access to this content.